GEP18-6
Diesel Generator Set Exclusively from your Cat ® dealer

EU Stage III Emissions Compliant Suitable for Mobile Applications in the European Community Image shown may not reflect actual package

Output Ratings
Generating Set Model - 3 Phase 380-415V,50Hz Prime* 16.5 kVA 13.2 kW 220/127V, 60 Hz 20.0 kVA 16.0 kW * Refer to ratings definitions on page 4. Ratings at 0.8 power factor.Standby* 18.0 kVA 14.4 kW 22.0 kVA 17.6 kW

Technical Data
Engine Make & Model: Alternator Model: Control Panel: Base Frame Type: Circuit Breaker Type: Frequency: Engine Speed: RPM Fuel Tank Capacity: litres (US gal) Fuel Consumption, Prime l/hr (US gal/hr) : Fuel Consumption, Standby: l/hr (US gal/hr) 4.4 (1.2) 4.8 (1.3) Perkins 404D-22G1 LL1114H DCP-10 Heavy Duty Fabricated Steel 3 Pole MCB 5 0Hz 1500 66 (17.4) 5.2 (1.4) 5.7 (1.5) 6 0 Hz 1800

Engine Technical Data
Physical Data
Manufacturer: Model: No. of Cylinders/Alignment: Cycle: Induction: Cooling Method: Governing Type: Governing Class: Compression Ratio: Displacement: l (cu.in) Bore/Stroke : mm (in) Moment of Inertia: kg m² (lb. in²) Engine Electrical System: -Voltage/Ground: -Battery Charger Amps: Weight: kg (lb) - Dry: -Wet: 12/Negative 65 242 (534) 251 (554) Perkins 404D-22G1 4 / In Line 4 Stroke Naturally Aspirated Water Mechanical ISO 8528 50 Hz-G2 23.3:1 2.2 (135.2) 84.0 (3.3)/100.0 (3.9) 2.72 (9308)

Lubrication system
Oil Filter Type: Total Oil Capacity Oil Pan l (US gal): Oil Type: Cooling Method: l (US gal): Spin-On, Full Flow 10.6 (2.8) 8.9 (2.4) API CH4 15W-40 N/A

P e r f o r m a nc e
Engine Speed:RPM Gross Engine Power: kW (hp) -Standby: -Prime: BMEP: kPa (psi) -Standby: -Prime: Regenerative Power: kW

50 Hz
1500 18.0 (24.0) 16.2 (22.0) 649.0 (94.2) 585.0 (84.8) 5.6

6 0 Hz
1800 21.5 (29.0) 19.4 (26.0) 647.0 (93.8) 583.0 (84.6) 7.2

Fuel System
Fuel Filter Type: Replaceable Element Class A2 Diesel l/hr (US gal/hr) 100% Load 75% Load 50% Load Recommended Fuel: Fuel Consumption:110% Load Prime 50 Hz 60 Hz Standby 50 Hz 60 Hz 4.8 (1.3) 5.7 (1.5) 3.7 (1.0) 4.4 (1.2) 2.7 (0.7) 3.3 (0.9) 4.8 (1.3) 5.7 (1.5) 4.4 (1.2) 5.2 (1.4) 3.4 (0.9) 4.0 (1.1) 2.6 (0.7) 3.1 (0.8)

A ir S y s t e m
Air Filter Type: Combustion Air Flow: m³/min (cfm) -Standby: -Prime: Max. Combustion Air Intake Restriction: kPa (in H2O) Radiator Cooling Air Flow: m³/min (cfm) External Restriction to CoolingAir Flow: Pa (in H2O)

50 Hz
Replaceable Element 1.5 (51) 1.5 (51) 3.0 (12.0) 33.0 (1165) 125 (0.5)

6 0 Hz

1.7 (61) 1.7 (61) 3.0 (12.0) 41.4 (1462) 125 (0.5)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

C o o li n g S y s t e m
Cooling System Capacity: l (US gal) Water Pump Type: Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby:-Prime:

50 Hz
6.5 (1.7)

6 0 Hz
6.5 (1.7)

Exhaust System
Silencer Type: Silencer Model & Quantity: Pressure Drop Across Silencer System: kPa (in Hg)

50 Hz

60 Hz

Industrial 263-0765 (1) 0.70 (0.207) 1.40 (0.413) 27 20 10.2 (3.0) 4.3 (151) 3.9 (138) 459 (858) 396 (745)

Centrifugal

Silencer Noise Reduction 15.2 (864) 13.7 (779) 17.2 (978) 15.5 (881) Level: dB Max. AllowableBack Pressure: kPa (in. Hg) -Standby: -Prime: Exhaust Gas Temperature: °C (°F) 413 (776) 364 (687) -Prime: -Standby: 10.2 (3.0) 3.2 (114) 3.0 (105) Exhaust Gas Flow: m³/min (cfm)

Heat radiated from engine and alternator Heat Radiation to Room: kW (Btu/min) -Standby: 5.8 (330) 6.3 (358) -Prime: 4.8 (273) 5.4 (307)

Radiator Fan Load:

kW (hp)

0.2 (0.3)

0.4 (0.5)

Cooling systemdesigned to operate in ambient conditions up to 50°C (122°F). Contact your local Olympian dealer for power ratings at specific site conditions.

Alternator Performance Data
5 0 Hz Data Item
415/240V 400/230V 380/220V

6 0 Hz
220/127V

Motor Starting Capability* kVA

38

36

33

-

-

-

-

-

36

Short Circuit Capacity %

-

-

-

-

-

-

-

-

-...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • olympia
  • Tasa Bruta De Suicidio Por Genero Y Grupos De Edad
  • Grupos De Trabajo Como Generadores De Destrezas Orales
  • Causas por las que se genera distraccion dentro del grupo escolar
  • Los grupos de trabajo como generadores de destreza orales
  • Semejanzas Y Diferencias Entre Grupos De Las Generaciones 30-90
  • Olympia De Manet
  • Acoso Genero Grupo

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS