Fourier
SA555 - SE555
®
GENERAL PURPOSE SINGLE BIPOLAR TIMERS
.
.
.
.
.
.
.
.
LOW TURN OFF TIME
MAXIMUM
OPERATING
FREQUENCY
GREATER THAN 500kHz
TIMING FROM MICROSECONDS TO HOURS
OPERATES IN BOTH ASTABLE AND
MONOSTABLE MODES
HIGH OUTPUT CURRENT CAN SOURCE OR
SINK 200mA
ADJUSTABLE DUTY CYCLE
TTL COMPATIBLE
TEMPERATURE STABILITY OF 0.005%
PERoC
DESCRIPTION
TheNE555 monolithic timing circuit is a highly stable
controller capable of producing accurate time delays
or oscillation. In the time delay mode of operation,
the time is precisely controlled by one external resistor and capacitor. For a stable operation as an oscillator, the free running frequency and the duty cycle are both accurately controlled with two external
resistors and one capacitor. Thecircuit may be triggered and reset on falling waveforms, and the output structure can source or sink up to 200mA. The
NE555 is available in plastic and ceramic minidip
package and in a 8-lead micropackage and in metal
can package version.
D
SO8
(Plastic Micropackage)
N
DIP8
(Plastic Package)
ORDER CODES
Part
Number
Package
N
D
0oC, 70oC
NE555
Temperature
Range•
•
SA555
–40 C, 105 C
•
•
SE555
–55oC, 125oC
•
•
o
o
PIN CONNECTIONS ( top view)
1
2
7
3
6
4
July 1998
8
5
1
2
3
4
5
6
7
8
-
GND
Trigger
Output
Reset
Control voltage
Threshold
Discharge
VCC
1/10
NE555/SA555/SE555
BLOCK DIAGRAM
VCC+
5kΩ
COMP
THRESHOLD
CONTROL VOLTAGE
DISCHARGE
R
FLIP-FLOP
Q5kΩ
COMP
OUT
TRIGGER
S
INHIBIT/
RESET
5kΩ
S
RESET
S - 8086
SCHEMATIC DIAGRAM
CONTROL
VOLTAGE
OUTPUT
THRESHOLD
COMPARATOR
5
VCC
R2
830W
R1
4.7kW
R3
4.7kW
R4 R8
1kW 5kW
R12
6.8kW
Q21
Q5
Q6
Q7
Q8
Q19
Q9
Q20
Q22
31R
3.9kW
R11
5kW
THRESHOLD
Q2
Q3
TRIGGER
2
Q23
R9
5kW
Q11 Q12
D2
RESET
4Q24
Q18
R16
100W
R15
4.7kW
Q15
7
Q17
Q14
GND
R14
220W
Q13
Q10
Q16
DISCHARGE
3
D1
R17
4.7kW
Q4
Q1
R5
10kW
R6
100kW
R7
100kW
R10
5kW
1
TRIGGER COMPARATOR
FLIP FLOP
ABSOLUTE MAXIMUM RATINGS
Symbol
Vcc
Toper
Tj
Tstg
2/10
Parameter
Value
Supply Voltage
Operating Free Air Temperature RangeJunction Temperature
Storage Temperature Range
18
for NE555
for SA555
for SE555
Unit
V
0 to 70
–40 to 105
–55 to 125
o
150
o
–65 to 150
o
C
C
C
NE555/SA555/SE555
OPERATING CONDITIONS
Symbol
VCC
Vth, Vtrig, Vcl, Vreset
Parameter
SE555
4.5 to 18
Maximum Input Voltage
4.5 to 18
V
VCC
Supply Voltage
NE555 - SA555
Unit
VCC
VELECTRICAL CHARACTERISTICS
Tamb = +25oC, VCC = +5V to +15V (unless otherwise specified)
Symbol
Parameter
SE555
NE555 - SA555
Vth
Ith
Vtrig
Itrig
Max.
3
10
2
0.5
30
0.05
Timing Error (astable)
(RA, RB = 1kΩ to 100kΩ, C = 0.1µF,
VCC = +15V)
Initial Accuracy - (note 2)
Drift with Temperature
Drift with Supply Voltage
VCL
Typ.
Timing Error (monostable)(RA = 2k to 100kΩ, C = 0.1µF)
Initial Accuracy - (note 2)
Drift with Temperature
Drift with Supply Voltage
ICC
Min.
1.5
90
0.15
Supply Current (RL ∞) (- note 1)
Low State
VCC = +5V
VCC = +15V
High State
VCC = 5V
Min.
Typ.
Max.
5
12
3
10
2
6
15
2
100
0.2
1
50
0.1
3
mA
0.5
2.25
150
0.3
V
9.6
2.9
10
3.33
10.4
3.8
92.6
10
3.33
11
4
Threshold Voltage
VCC = +15V
VCC = +5V
9.4
2.7
10
3.33
10.6
4
8.8
2.4
10
3.33
11.2
4.2
0.1
0.25
0.1
0.25
5
1.67
5.2
1.9
5
1.67
5.6
2.2
0.5
0.9
0.5
2.0
0.7
1
0.7
1
V
Threshold Current - (note 3)
Trigger Voltage
VCC = +15V
VCC = +5V
Reset Voltage - (note 4)
0.4
4.5
1.1...